Bubble 2 Overlay Alternating
An alternating pressure mattress overlay system. It is specifically designed as an entry-level solution for the prevention and treatment of pressure sores (bedsores) in patients at low risk for developing them. This system is a popular choice for home care, nursing homes, and clinical environments due to its simple setup and effective pressure redistribution. £49 Ex VAT Key Product Features Alternating Pressure Technology : The mattress consists of 130 individual bubble cells that alternate in a cycle of inflation and deflation. This constantly changes the pressure points against the patient's skin, which helps improve circulation and prevents tissue breakdown. Manual Adjustment Pump : The included pump features a straightforward pressure adjustment dial . This allows caregivers to manually set the firmness based on the patient's specific weight and comfort requirements. Hygienic Design : It is manufactured from water-resistant and antimicrobial materials, making it easy to clean and helping to maintain a sterile environment. Secure Fit : The overlay includes tuck-in extension flaps at the top and bottom to ensure it stays securely in place on top of an existing standard mattress. Compact & Portable : Both the mattress and the pump are lightweight, making the system easy to transport or store when not in use. Technical Specifications Feature Details User Risk Level Low Risk Max User Weight 135 kg (approx. 21 stone) Mattress Dimensions 200 x 90 x 7 cm Cycle Time Standard alternating cycle (typically ~10-12 mins) Pump Type Entry-level analogue pump Usage Note As an overlay system , this product must be placed on top of an existing foam mattress . It is not intended to be used as a standalone mattress.

Pearl Overlay Alternating
A dynamic air-flow solution specifically engineered for patients at medium to high risk of developing pressure ulcers. This system is commonly utilised in hospitals, nursing homes, and residential care environments to provide effective pressure redistribution and comfort. £209 Ex VAT Core Functionality The system features 5-inch air cells that operate on a 12-minute alternating cycle . By periodically inflating and deflating different sections, the mattress ensures that pressure is not continuously applied to any single part of the patient's skin, which helps improve blood circulation and prevents tissue breakdown. Key Features & Benefits Targeted Pressure Care : Designed with independently removable, nylon TPU-coated air cells for easy maintenance and hygiene. User Comfort : Includes a dedicated pillow function for added head support and micro-perforated cells to enhance air circulation and reduce moisture build-up. Simple Operation : The entry-level analogue pump is designed for ease of use, allowing caregivers to quickly set optimal pressure based on the patient's weight. Hygienic Cover : Comes with a multi-stretch PU cover that is waterproof, vapour-permeable, antimicrobial, and machine-washable. Emergency Safety : Features a CPR release toggle for rapid deflation during emergency procedures. Technical Specifications Feature Details Max User Weight 160 kg (25 stone) Mattress Dimensions 200 x 90 x 12.7 cm (78.5 x 35.5 x 5") Cycle Time 12 Minutes Modes Alternating and Static modes Safety Alarms Visual and audible alarms for low pressure and power failure Fire Safety Complies with BS7177: Crib 5 regulations

Emerald 2 Overlay Alternating System
A high-performance alternating pressure mattress overlay system. It is specifically designed for the prevention and treatment of pressure ulcers in patients at high risk of developing bedsores. Building on the features of the Pearl system, the Emerald 2 offers enhanced durability and advanced pump technology for more demanding care environments like hospitals and nursing homes. £269 Ex VAT Key Product Features Advanced Alternating Therapy : Features 2-inch or 5-inch air cells (depending on the specific overlay version) that alternate on a 12-minute cycle , ensuring continuous pressure redistribution and improved blood flow to vulnerable areas. SensaCare Truflo Technology® : The pump utilises advanced sensors to maintain consistent air pressure, even when the patient moves or changes position. Static Mode : Can be switched to a static state to provide a firm, stable surface for patient transfers or nursing procedures. Ultra-Quiet Pump : Designed to operate with minimal noise and vibration, ensuring the patient’s sleep and rest remain undisturbed. Safety & Security : Visual and Audible Alarms : Immediately alerts caregivers to low pressure or power failure. CPR Release : A quick-access toggle for rapid deflation in emergency situations. Non-Slip Base : Prevents the overlay from sliding on the underlying mattress. Protective Cover : Includes a multi-stretch, vapour-permeable, and waterproof PU cover that is antimicrobial and machine-washable. Technical Specifications Feature Details User Risk Level High Risk Max User Weight 150 kg (approx. 23.5 stone) Mattress Dimensions 200 x 90 x 12.7 cm (5" version) Cycle Time 12 Minutes Material Nylon TPU-coated cells / PU Stretch cover Fire Safety Complies with BS7177: Crib 5 Comparison Note Compared to the Pearl (Medium-High Risk) and the Bubble 2 (Low Risk), the Emerald 2 is built for more intensive care, featuring more robust pump controls and higher-grade materials for superior skin protection.

Emerald Auto Alternating Mattress
A high-specification overlay alternating pressure mattress system designed for the prevention and treatment of patients at high risk of developing pressure ulcers. This "Auto" version is the most advanced in the Emerald range, featuring automatic weight-sensing technology that continuously adapts air pressure to the user's weight and position without requiring manual input from a caregiver. £435 Ex VAT Key Product Features Auto Weight Sensing : Utilises SensaCare Truflo Technology® to automatically detect a patient's weight and adjust interface pressures for personalized support. Remote Control : Includes a dedicated remote that allows both patients and caregivers to adjust cycle times, activate the auto-firm function (for transfers), or use seat inflation for seated comfort. Advanced Cell Design : Features 5-inch independently removable air cells made from durable Nylon TPU. Micro-perforated cells enhance air circulation to reduce heat and moisture build-up. Operating Modes : Alternating : Standard therapy for pressure redistribution. Static : Provides a firm, stable surface for nursing procedures. Max Firm : Rapidly inflates to maximum pressure to assist with patient repositioning. Safety Alarms : Equipped with visual and audible alerts for low pressure, power failure, or alternate failure. Clinical Integrity : Includes a CPR quick-release toggle for emergency deflation and a non-slip base with anchoring straps for stability. Technical Specifications Feature Details User Risk Level High Risk Max User Weight 160 kg (25 stone) Mattress Dimensions 200 x 90 x 12.7 cm (78.5 x 35.5 x 5") Cycle Times 10, 15, 20, or 25 minutes Fire Safety Complies with BS7177: Crib 5 Cover Type Multi-stretch PU, waterproof, vapour-permeable, antimicrobial

Sapphire 2 Replacement Alternating System
An advanced alternating pressure relieving replacement mattress system . Unlike the previous models discussed, which are overlays, this is a full replacement mattress designed for patients at high risk of developing pressure ulcers in clinical or home care settings. £389 Ex VAT Key Features and Benefits Dual-Core Protection : It features 5-inch air cells over a 2-inch self-inflating sealed foam base , providing a total in-use height of 7 inches. This foam base ensures that even in a power failure, the patient is never "bottoming out" against the bed frame. SensaCare Truflo Technology® : The pump uses automatic pressure sensing to provide ultra-low interface pressure, promoting stable blood circulation and natural sleep patterns. Targeted Heel Care : Includes a specialised heel function with removable cells that can be repositioned to create zero pressure directly under a heel ulcer. Versatile Operating Modes : Alternating Mode : For continuous pressure redistribution. Static Mode : Provides a firm, stable surface for patient transfers or nursing care. Max Firm Mode : Quickly inflates the mattress to maximum pressure for rapid positioning. Quiet & Safety Focused : The pump features Ultra-Silent™ operation to minimize sleep disturbance and includes visual and audible alarms for low pressure or power failure. Technical Specifications Feature Details Risk Category High Risk Max User Weight 200 kg (approx. 31.5 stone) Mattress Dimensions 200 x 90 x 18 cm (including foam base) Cycle Times Adjustable: 10, 15, 20, or 25 minutes Cover Multi-stretch PU, waterproof, antimicrobial, machine washable Safety Compliance BS7177: Crib 5 fire rating

Ruby 2 Replacement Alternating System
A top-tier very high-risk replacement alternating pressure mattress system . It is specifically engineered for the prevention and treatment of patients at the highest risk of developing pressure ulcers, often used in intensive care and long-term clinical settings. As a full replacement system, it features a "cell-on-cell" design , meaning each 8-inch air cell contains a secondary inner cell that remains permanently inflated. This provides a critical safety layer, preventing the patient from "bottoming out" in the event of a power failure. £579 Ex VAT Key Features & Benefits Cell-on-Cell Technology : The 8-inch (20cm) deep air cells provide superior immersion and envelopment. The integrated static base layer ensures the patient is supported even during a total loss of power. Advanced Remote Control : Allows both caregivers and patients to manage the system conveniently. It controls cycle times, mode selection, and firmness without needing to access the main pump unit. SensaCare Truflo Technology® : Features an ultra-quiet pump with digital pressure sensors that constantly monitor and adjust the internal pressure to match the patient’s body weight and movement. Multi-Functional Modes : Alternating : Active therapy for maximum pressure redistribution. Static/Constant Low Pressure : Provides a stable surface for repositioning or transfers. Max Firm : Rapidly inflates to facilitate quick nursing interventions. Seat Inflation : Increases pressure in the sacral area when the bed head is raised, preventing the patient from sinking. Heel Care Function : The lower cells can be individually disconnected to create a "zero pressure" zone for targeted heel ulcer treatment. Clinical Safety : Includes a rapid-access CPR toggle, visual/audible alarms for low pressure or power loss, and a Crib 5 fire-rated, antimicrobial, multi-stretch cover. Technical Specifications Feature Details Risk Category Very High Risk Max User Weight 200 kg (approx. 31.5 stone) Mattress Dimensions 200 x 90 x 20 cm (8") Cycle Times Variable: 10, 15, 20, or 25 minutes Safety Alarms Low pressure, Power failure, Alternate failure Cover Multi-stretch PU, Vapour permeable, Waterproof

Ruby Auto
The flagship very high-risk replacement alternating pressure mattress system . It is the most sophisticated model in the range, combining a deep "cell-on-cell" design with fully automatic weight-sensing technology . This system is designed for patients at the highest risk of developing pressure ulcers, providing maximum protection and autonomous adjustment in hospitals and high-dependency care environments. £929 Ex VAT Key Product Features Automatic Weight Sensing : Utilising SensaCare Truflo Technology® , the pump automatically detects the patient's weight and continuously adjusts internal air pressure. This eliminates the risk of manual setting errors and ensures optimal pressure redistribution at all times. Cell-on-Cell Safety Design : The mattress features 8-inch (20cm) deep air cells . Each cell has an integrated inner "static" cell that remains permanently inflated. This ensures that even during a power outage or total pump failure, the patient is never left resting directly on the bed frame. Advanced Remote Control : Provides caregivers and patients with wireless access to all functions, including cycle time adjustments (10, 15, 20, or 25 minutes) and mode selection. Specialized Therapeutic Modes : Alternating : Active therapy for continuous pressure point shifting. Static : Creates a firm surface for stable patient transfers or medical procedures. Max Firm : Rapidly inflates the system to its highest pressure for immediate repositioning needs. Seat Inflation : Increases support in the sacral area when the patient is in a seated position to prevent "bottoming out." Heel Care Function : The lower three cells can be individually disconnected to create a "zero pressure" zone, essential for treating existing heel ulcers. Technical Specifications Feature Details User Risk Level Very High Risk Max User Weight 200 kg (approx. 31.5 stone) Mattress Dimensions 200 x 90 x 20 cm (8") Cycle Times 10, 15, 20, or 25 minutes Alarms Low pressure, Power failure, Alternate failure Cover Multi-stretch PU, Vapour permeable, Waterproof, Antimicrobial Why Choose the Ruby Auto? Unlike the Ruby 2 , which requires manual pressure settings via the remote or pump, the Ruby Auto manages the pressure autonomously. This makes it the ideal choice for busy clinical settings where caregiver time is limited and patient safety is the highest priority.

Bariatric 2 Replacement System
A heavy-duty, very high-risk replacement alternating pressure mattress system . It is specifically designed to provide effective pressure relief and support for bariatric patients who are at significant risk of developing pressure ulcers. This system is wider and more robust than standard models, featuring a "cell-on-cell" design that ensures the patient remains supported by a secondary internal layer of air even during power failures. £1399 Ex VAT Key Product Features Bariatric Support : Engineered with a wider surface area (120cm) and reinforced components to safely support users weighing up to 350 kg (approx. 55 stone) . Cell-on-Cell Safety : The 10-inch deep air cells contain an inner static cell that stays permanently inflated. This "fail-safe" prevents the patient from bottoming out against the bed frame if the pump loses power. SensaCare Truflo Technology® : The pump features advanced digital sensors to provide ultra-low interface pressure. It maintains consistent airflow and pressure regardless of patient movement. Advanced Remote Control : Includes a wireless remote, allowing caregivers to manage settings—such as cycle times and inflation modes—from anywhere in the room. Therapeutic Modes : Alternating : Standard cycle for active pressure redistribution. Static : Provides a firm surface for nursing tasks or patient transfers. Max Firm : Rapidly inflates the system to its highest pressure for immediate repositioning. Seat Inflation : Boosts pressure in the sacral area when the patient is in a seated position. Safety & Hygiene : Features a rapid-release CPR toggle for emergencies, a non-slip base, and a vapour-permeable, waterproof, antimicrobial cover that is machine-washable. Technical Specifications Feature Details User Risk Level Very High Risk Max User Weight 350 kg (55 stone) Mattress Dimensions 200 x 120 x 25 cm (10" depth) Cycle Times 10, 15, 20, or 25 minutes Alarms Low pressure, Power failure, Alternate failure Fire Safety Complies with BS7177: Crib 5 Comparison Note While the Ruby Auto focuses on automatic weight sensing for standard weights, the Bariatric 2 prioritizes high weight capacity and a wider footprint, making it essential for larger patients requiring intensive pressure care.

Sensaflo Hybrid Replacement System
A versatile 4-in-1 hybrid mattress system designed for patients at very high risk of developing pressure ulcers. It is an ideal solution for hospital, nursing home, and home care environments where patient needs may evolve over time. 90cm - £679 Ex VAT 120cm - £839 Ex VAT Comprehensive 4-in-1 Design The Sensaflo Hybrid is uniquely engineered to provide four distinct support options within a single unit : Static Foam Mattress : Without the pump, it functions as a high-specification foam mattress for stable support. Alternating Air System : When connected to the pump, it becomes a dynamic alternating pressure system for active relief. Self-Adjusting Air Mattress : By inflating and then sealing it with a transport cap, you create a semi-active, balanced-air surface. Built-in Evacuation System : Integrated straps and handles allow for rapid patient transport directly on the mattress during emergencies without needing a transfer. Key Features & Benefits Adaptive Heel Zone : Features four removable SensaGel gel-foam pads that can be repositioned to create a "zero pressure" zone specifically for vulnerable heels. SensaCare Truflo Technology® : The pump utilizes automatic pressure sensing and a microcomputer regulator to maintain ultra-low interface pressure while remaining Ultra-Silent™ for undisturbed sleep. User Comfort & Positioning : Includes an ergonomically castellated pillow function and profiling side sections that allow the mattress to flex seamlessly with profiling bed frames. Safety & Hygiene : CPR Release : Quick-access toggle for rapid deflation in medical emergencies. Protective Cover : Multi-stretch, water-resistant, and antimicrobial PU cover with welded seams and a 360-degree zipper for easy maintenance. Fire Safety : Fully complies with BS7177: Crib 5 fire safety regulations. Technical Specifications Feature Details User Risk Level Very High Risk Max User Weight 250 kg (approx. 39 stone) Mattress Dimensions 198 x 90 x 15 cm (standard) or 120 cm (bariatric) Pump Cycle Times Adjustable: 10, 15, 20, or 25 minutes Alarms Visual and audible for low pressure, power failure, and alternate failure

Simple Air 2
An advanced dynamic replacement mattress system designed for individuals at high risk of developing pressure ulcers . This system combines active pressure redistribution with user-friendly digital controls to provide a comprehensive care solution for home or clinical environments. £499 Ex VAT Key Therapeutic Features Dynamic Air Therapy : Features 20 air cells arranged in a "cell-on-cell" structure. This includes 17 alternating body cells and 3 static head cells that provide a "pillow function" for stability and comfort. 1-in-2 Alternating Cycle : The mattress uses an AB alternating pattern to shift pressure points every 10, 15, or 20 minutes , effectively redistributing weight and promoting circulation. Versatile Operating Modes : Alternating Mode : Actively prevents ulcers by shifting pressure. Static Mode : Provides a firm, stable surface for patient transfers or nursing procedures. Auto-Firm Function : Rapidly inflates to maximum firmness to assist with patient positioning. Transport Mode : Maintains inflation for a period to allow for easy patient movement between locations. Safety & Hygiene Emergency CPR Release : A dedicated pull-tag CPR at the head end allows for rapid deflation in the event of a cardiac emergency. Comprehensive Alarms : Includes both audible and visual low-pressure alerts to notify caregivers of any system issues. Infection Control : The dark blue cover features welded seams and a 360-degree zipper . It is multi-stretch, water-resistant, and vapour-permeable to protect the internal cells from fluid ingress. Cable Management : Integrated routing helps organize power cables neatly, reducing trip hazards and enhancing overall safety. Technical Feature Specification Max User Weight 200 kg (approx. 31.5 stone) Mattress Dimensions 200 cm (L) x 88 cm (W) x 20 cm (D) Pump Weight 3.4 kg Total Product Weight 10.4 kg Cycle Times 10, 15, or 20 minutes Warranty 2 Years

Simple Plus (Bariatric)
A dynamic mattress replacement system specifically engineered for plus-size or bariatric patients at high risk of developing pressure ulcers . Unlike overlay systems, this is a full replacement mattress designed to support heavier individuals without the need for an underlying mattress. £899 Ex VAT Key Therapeutic Features High-Capacity Dynamic Support : Specifically designed for bariatric care, with weight capacities available for users up to 300 kg (47 stone) or 400 kg (63 stone) . Advanced Cell Therapy : Features 20 air cells (typically 16–17 alternating and 3–4 static head cells) in a cell-on-cell configuration. This ensures the patient is supported by a secondary air layer even during power outages. 1-in-2 Alternating Cycle : Actively shifts pressure points across the body to promote healthy circulation and prevent tissue damage. Adjustable Cycle Times : Care teams can customize therapy intensity with adjustable cycles of 10, 15, 20, or 25 minutes . Operational Modes Alternating Mode : Provides continuous dynamic pressure redistribution. Static Mode : Offers a firm, stable surface for patient transfers or nursing procedures. Auto-Firm Setting : Rapidly inflates all cells to maximum pressure to assist with clinical tasks. Seat Inflate Setting : Provides additional support in the lumbar and leg regions when the patient is in a seated position to prevent "bottoming out". Safety & Hygiene CPR Rapid Deflation : Easily accessible red pull tags allow for instant deflation during medical emergencies. Intelligent Alarms : Features both visual and audible alerts for low pressure, power failure, or alternate failure. Infection Control : The mattress comes with a multi-stretch PU cover that is waterproof, vapour-permeable, and antimicrobial. It features welded seams and a 360-degree zipper to prevent fluid ingress and simplify cleaning. Auto Lock-Out : Automatically locks the pump controls after five minutes of inactivity to prevent accidental changes to settings. Technical Specifications Dimensions : 200 cm (L) x 120 cm (W) x 26 cm (D). Weight : Mattress approx. 7 kg; Pump approx. 3.5 kg. Pump Output : 12 litres per minute airflow for rapid inflation. Warranty : 2 Years.

Auto One Dynamic System
A cost-effective, automatic dynamic mattress system designed for the prevention and treatment of pressure ulcers in patients at high risk . It is suitable for use in hospital, residential, and home care environments. £629 Ex VAT Intelligent Pressure Management The standout feature of this system is the Automatic Pressure Setting , which uses digital sensors to detect a patient's weight and automatically set the optimum internal air pressure. This reduces the risk of manual setting errors while still allowing caregivers the flexibility to fine-tune comfort levels manually. Key Therapeutic Modes Alternating Mode : Provides active pressure redistribution using a 2-in-1 (AB) pattern over customisable cycles of 10, 15, 20, or 25 minutes . Static Mode : Maintains a constant surface pressure across all cells for stable patient transfers or medical procedures. Seat Mode : Automatically increases internal cell pressure by 10% when the bed backrest is raised beyond 25° to prevent "bottoming out" in the sacral area. Max Inflate : Rapidly inflates all cells to maximum firmness to assist with patient repositioning; the pump automatically reverts to the previous setting once finished. Mattress Construction & Safety Air-on-Air Design : Features 20 top cells (including 3 static head cells for a "pillow" function) and a base layer of 20 static air cells. This dual-layer construction ensures the patient remains supported even during power failures. Emergency Features : A clearly marked CPR dial at the foot end allows for rapid deflation during cardiac emergencies. Infection Control : The multi-stretch, vapour-permeable, and waterproof cover features welded seams and a 360° zip to prevent fluid ingress and simplify deep cleaning. Integrated Safety : Includes a zipped cable management system to reduce trip hazards and audible/visual alarms for low pressure or power loss. Technical Feature Specifications Max User Weight 225 kg (35.5 stone) Mattress Dimensions 203 cm (L) x 90 cm (W) x 20 cm (D) Setup Time Ready for patient in 30 mins; fully set up in 40 mins Compliance EN60601-1, EN60601-1-2, and EN60601-1-11 Warranty 2-year parts warranty